SHR3E Mini intelligentsoft starter

SHR3E series soft starter is SHUOSHI electric combination of industry experienceand application of the special needs of customers a profoundunderstanding of product development in the multi-year productdevelopment based on the introduction of the new integrated intelligent motor control and protectionproducts, adding new features lmprove customer application reliability and convenience

Request a Quote

PRODUCTS DETAILS

Product Profile

The SHR3E soft starter is a brand-new integrated inteligent motor control and protection product launched by shuoshi Electric, Combining richexperience in industry applications and a deep understanding of customers special application requirements, and based on years ot product
research and development, it has added new functions, improving the reliability and convenience of customer applications.

The soft starter is a digital motor soft starting product. It can control the motor to accelerate smoothly during the starting process and deceleratesmoothly during the stopping process, and it provides protection functions for both the motor and the produc itself it is the best upgradedalternative to traditionalstar-delta and reactor starters. t is suitable for asynchronous squirelcage motors with a power range of0.75-90kW.

The soft starter is equipped with an RS485 communication interface and supports the Modbus protocol, enabling comprehensive remote controland monitoring by a microcomputer. It can be widely used in industries such as textiles, metallurgy, agriculture, petroleum, chemical watertreatment, shipping, transportation, pharmaceuticals, food processing, mining, and mechanical equipment.

Function

The SHR3E series soft starters can directly set the parameters of starting time, stopping time and initial voltage through three potentiometersAll models in the SHR3E series soft starters have built - in bypass relays. Users do not need to additionally install external bypass contactors.The soft start adopts the voltage ramp starting method.

During the soft stop process,the output torque can be maintained (final torque control), thus effectively preventing the water hammer effectt can adont two connection methods, delta externalconnection and star externa connection.Real -time data (phase A current, phase B current, phase C curent, average current, etc,) can be read through communication.*NoteFault history records (10 fault history records, etc,) can be read through communication. *NoteStatistical data (cumulative number of starts, cumulative running time,cumulative number oftrips, etc,) can be read through communication.*Note

Protection functions of the SHR3E series soft starters:

1)Over-current protection
2)Over-current delay protection
3) Over - load protection (Over -load class: CLASS10A, CLASS10,CLASS20,CLASS30)
4)Three-phase currentimbalance protection
5)Phase loss/under-voltage protection
6)Phase sequence protection
7)SCR (Silicon -Controlled Rectifier) over-temperature protection

There is one start/stop control input point.
RS-485 communication bus interface.*Note
It is optional to have a built -in start/stop control switch.*Note
There are two relay outputs (running relay and fault relay).

*Note 1: lt is an optional accessory,. This function can only be used when the Rs -485 communication bus interface (Modbus RTU protocol is selected

*Note 2: lt is an optional accessory. This function can only be used when the buit -in start/stop control switch is selected.

Features

  • Three-phase control;
  • Operating voltage: 200/400/500VAC;
  • Wide range of control voltage: 100~240VAC 50/60Hz or 24VDC;
  • SLR rated operating current: 1.5~150A;
  • The control board is added with a protective coating;
  • Direct parameter setting via potentiometers makes the setting and operation simpler and more convenient.All series have built-in bypass, which reduces energy consumption and is easy to install;
  • Modbus RTU is optional for monitoring;
  • Supports all mainstream communication protocols,
  • Built-in motor protection function;
  • Integrated structure design with a protection level of lP21:It can effectively resist dust, moisture and corrosive gases, significantly extending the service life.

Feature Description

Input Voltage 220/400/500VAC 50/60Hz
Control Source
Voltage
100~240VAC or 24VDC 50/60Hz
Current class 1.5……150A
Initial Voltage 30%~70%
Start Slope 1~30Sec
Stop Slope 0~30Sec
Overload 3 x le for 7 Sec
Valid for 50 % on time and 50 % off time.
Times of start per hour <5,5-10 (light load or no-load)
Overload grade 10A
Operation Environmental
temperature
0℃to+50℃(32℉to122℉)
Store temperature -40℃to+70℃(-40℉to158℉)
Maximum altitude 1000m (3280ft)
Ingress Protection grade IP21

未标题-1.jpg

Note:
1. Rated voltage ofthe main power supply: 22:220V; 40:400V; 50: 500V;
2. Rated current: 1.5~150A;
3.Control power supply voltage: A: 100~240VAC; B: 24VDC;
4. Control mode of the soft starter: 3P3: Three-phase three-control; 1P1: Single-phase single-control.

Internal control form of the soft starter

未标题-2.jpg

Application internal & External connection

未标题-3.jpg

Product Selection

Model Motor power rating SLR Rated
operational current
Structure Weight
220V
Pe/kW
400V
Pe/kW
500V
Pe/kW
le
A
F kg
SHR3EXX1T5-X-3P3 0.37 0.75 1.1 1.5 A 1
SHR3EXX2T2-X-3P3 0.55 1.1 1.5 2.2 A 1
SHR3EXX03-X-3P3 0.75 1.5 2.2 3 A 1
SHR3EXX4T5-X-3P3 1.1 2.2 3.7 4.5 A 1
SHR3EXX7T5-X-3P3 1.5 3.7 5.5 7.5 A 1
SHR3EXX11-X-3P3 2.2 5.5 7.5 11 A 1
SHR3EXX 15-X-3P3 3.7 7.5 11 15 B 1.4
SHR3EXX22-X-3P3 5.5 11 15 22 B 1.4
SHR3EXX30-X-3P3 7.5 15 18.5 30 C 2.4
SHR3EXX37-X-3P3 11 18.5 22 37 C 2.4
SHR3EXX45-X-3P3 15 22 30 45 C 2.4
SHR3EXX60-X-3P3 18.5 30 37 60 C 2.4
SHR3EXX75-X-3P3 22 37 45 75 C 2.4
SHR3EXX90-X-3P3 25 45 55 90 D 5
SHR3EXX110-X-3P3 30 55 75 110 D 5.2
SHR3EXX150-X-3P3 37 75 90 150 D 5.2

Note:

1、1T5 means 1.5A,4T5 means 4.5A,7T5 means 7.5Ain Rated current.
2、Other voltage classes can be made to order.

Model Motor power rating SLR Rated
operational current
Structure Weight
220V
Pe/kW
400V
Pe/kW
le
A
F kg
SHR3EXX02-X-1P1 0.37 0.55 2 A 1
SHR3EXX03-X-1P1 0.55 0.75 3 A 1
SHR3EXX04-X-1P1 0.75 1.1 4 A 1
SHR3EXX06-X-1P1 1.1 1.5 6 A 1
SHR3EXX09-X-1P1 1.5 2.2 9 A 1
SHR3EXX12-X-1P1 2.2 3.7 12 A 1
SHR3EXX20-X-1P1 3.7 5.5 20 C 2.4
SHR3EXX30-X-1P1 5.5 7.5 30 C 2.4
SHR3EXX37-X-1P1 7.5 11 45 C 2.4

In applications with conventional loads:

Such as water pumps, compressors, ventilation equipment, conveying equipment, etc.The SHR3E soft starter can be selected according to the rated power of the electric motor(Note: For heating equipment, the selection can be made according to the rated current.)

For applications with heavy loads:

such as centrifugal fans, mixers, grinders, blenders, or equipment that needs to befrequently started within a short period of time, SOSlCN recommends that you selecta soft starter one rating higher than the rated power of the electric motor.

Application Diagram

未标题-5.jpg

Parameters

General
Frequency 50/60Hz±5Hz
Rated Main Voltage 220-500±10% VAC(chose by customer); 400VAC±10%(acquiescent)
Control Source Voltage 100-240VAC-15%+10% or 24VDC(chose by customer);100-240VAC±10%(acquiescent)
The motor adapted Three-phase squirrel-cage induction motor
Times of start per hour <5 at 400% FLA
Operating data
Motor rated operational current Motor full load current: 1.5-150A
Initial voltage 30%~70% Un
Start Slope 1-30 seconds
Stop Slope 0-30 seconds
Motor protections
Over current During start , operation , stop , output current over limit
Unbalanced Current Output current unbalanced level beyond the setting
I²t overload May set to 10A,10… overload protection base on the setting to delay protection stop
Missing phase/ No voltage Stop the softstarter when 1 or 2 phases failed Or no voltage input
Thyristor(SCR) overtemp Stop the softstarter when the radiator temperature rises above 80℃
Phase sequence Forbid starting when the input phase sequence is wrong
( If the function is unnecessary, please tell us before ordering)
Under current Stop the softstarter when the current lower than under current protection value
Max start time Stop the softstarter when the time of starting process exceeds the max start time

Rapid fuse

Model SCRI²T(A²S) Fuse rating
SHR3EXX1T5-X-3P3 70 5A
SHR3EXX2T2-X-3P3 150 10A
SHR3EXX03-X-3P3 270 10A
SHR3EXX4T5-X-3P3 610 16A
SHR3EXX7T5-X-3P3 1700 25A
SHR3EXX 11-X-3P3 3630 32A
SHR3EXX 15-X-3P3 5000 40A
SHR3EXX22-X-3P3 7500 50A
SHR3EXX30-X-3P3 10000 63A
SHR3EXX37-X-3P3 11000 100A
SHR3EXX45-X-3P3 12000 160A
SHR3EXX60-X-3P3 15000 200A
SHR3EXX75-X-3P3 18000 250A
SHR3EXX90-X-3P3 40000 315A
SHR3EXX110-X-3P3 60000 315A
SHR3EXX150-X-3P3 100000 400A

Product Structure Size

SHR3E-3.jpg

Schematic Diagram

未标题-4.jpg

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours

Leave YourMessage

Thank you! We will reply you via email within 24 hours.

Return