SHR2DN Heavy Load Soft Starter

SHR2DN is a new intelligent motor soft starter, SHR2DN withthe most advanced digital processor which can adjust voltageand limit the electric current. The unique intelligent electronic circuit offers perfect control andprotective function: Start linearly with higher speed, starting and stopping control of the pumppreset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realizeautomatically run with energy-saving or light load mode. The protective function of electricalmachinery insulating testing , and the protection of short circuit, phase loss and the electronicRS485 with communication interface use modbus/profibus protocol that generally realize the long.range control and monitoring. Can be extensively used in textile industry, metallurgy industrypetrochemical industry, water treatment, shipping industry, medicine, food processing industrymine industry and mechanical equipment industry etc.

Request a Quote

PRODUCTS DETAILS

Product Profile

SHR2DN is a new intelligent motor soft starter,SHR2DN withthe most advanced digital processor which can adjust voltageand limit the electric current. The unique intelligent electronic circuit offers perfect control andprotective function: Start linearly with higher speed, starting and stopping control of the pumppreset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realizeautomatically run with energy-saving or light load mode. The protective function of electricalmachinery insulating testing , and the protection of short circuit, phase loss and the electronicRS485 with communication interface use modbus/profibus protocol that generally realize the long.range control and monitoring. Can be extensively used in textile industry, metallurgy industrypetrochemical industry, water treatment, shipping industry, medicine, food processing industrymine industry and mechanical equipment industry etc.

Function

  • Multinational language supported, LcD display, set up the parameter in button type
  • RS485 with communication interface modbus/profibus protocol
  • Can programme set the signal relay
  • Super strong perfect control and protective function
  • Can be run online continuously without bypass. High reliability

Soft starter  202003 PriVersion3(1)-42.jpg

Parameters

230-690V Motor Power
Motor Power (KW) Size and Type of softstarter
230V 400V 500V 690V   Main
voltage
Control
voltage
Control
inputs
Functions
Options
4 7.5 11 15 SHR2DN17 -x -x -x -× + X…
7.5 15 18.5 25 SHR2DN31 -x -x -x -× + ×…
15 22 25 37 SHR2DN44 -x -x -x -x + x…
18.5 30 37 55 SHR2DN58 -x -x -x -× + ×…
22 37 45 59 SHR2DN72 -x -x -x -x + x…
25 45 55 75 SHR2DN85 -x -x -x -× + ×…
30 55 75 90 SHR2DN105 -x -x -x -× + ×…
37 75 90 132 SHR2DN145 -x -x -x -x + x…
45 90 110 160 SHR2DN170 -x -x -x -× + ×…
55 110 132 200 SHR2DN210 -x -x -x -×+ ×…
75 132 160 220 SHR2DN250 -x -x -x -X + X…
90 160 200 257 SHR2DN310 -x -x -x -× + ×…
110 200 250 355 SHR2DN390 -x -x -x -X + X…
132 250 315 450 SHR2DN460 -x -x -x -× + ×…
160 315 400 560 SHR2DN580 -x -x -x -×+×…
200 400 500 710 SHR2DN720 -x -x -x -× + ×…
250 450 560 800 SHR2DN820 -x -x -x -x + x…
280 500 630 850 SHR2DN950 -x -x -x -X + X…

Purchasing guide
For normal duty applications, we recommend the same rated power HPS2DN softstarters. As pump compress or elevator, escalator conveyor belt(short)For heavy duty applications, we recommend one higher level HPS2DN soft starters.As centrifugal, fan,mill,mixer conveyor belt(long)

Parameters

General information
Supply voltage Line to line 230V-690V (to be specified) 10%
Frequency 50/60Hz 4Hz(dual frequency)
Control Supply 110-120V of 220-240V (to be specified)
Control Inputs and Outputs 110-120V of 220-240V (to be specified)
Load 3 phase, 3 wire, squirrel cage induction motor
Operating temperature 0℃ to 50℃
Storage temperature -20 ℃t o 70℃
Maximum starting time 30 seconds
Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower
load applications
Operating parameters
Starter FLC Starter Full Load Current 17~950 Amp
Motor FLA Motor Full Load Ampere 50%-100% of starter FLC
Pump control curves 6 field selectable curves preventing over pressure during start and water
hammer during stop
Pulse start duration A pu lse of 80% Un for adjustable time 0-1 second, to start high friction loads
Initial voltage 10%-50% Un*(can be extended to 80% Un)
Current limit 100%-400% of Motor FLA* (can be extended to 500%)
Ramp-up time 1-30 seconds (can be extended to 90s*)
Ramp-down time 1-30 seconds(can be extended to 90s*)
Dual adjustments Secondary start stop characteristics for Initial voltage, current limit,
acceleration time deceleration time and motor FLA.
Energy saving Activated when motor is lightly loaded for extended periods of time
Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to
a maximum of 30 seconds
Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tach o feedback linearity
Starting from diesel generator Special starting characteristics become operative via an internal dip switch.
(contact terminal 8, for dual adjustment)
Motor protection
Too many starts Determines maximum number of starts allowable during Start Period
Rangel-10starts in start period 1-60minutes
Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO
MANY STARTS is indicated
Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum
start time of 1-30 seconds*
Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850%
in during running
Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected
by setting trip time at 500% in,1-10 seconds
Under current Starter trips when current drops below 20%-90% In, time del ay 1-40 seconds
Under voltage(**) Starter trips when mains voltage drops below 120–600V, time del ay 1–10 seconds
Over voltage Starter trips when mains voltage increases above 150-750Vtime del ay 1-10 seconds
Phase loss,(under/ over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency
Phase sequence Starter trips when phase sequence is incorrect
Long slow speed time Starter trips if operating at slow speed longer than 30 seconds
Wrong connection Prevents starting if the motor is incorrectly connected to the starter
Shorted SCR Prevents starting when one or more SCRs are shorted
Heatsink over temperature Starter trips when heatsink temperature rises above 85
External fault Starter trips when an external contact closes for 2 seconds
Motor insulation(optional) Alarm level setting 0.2-5M. Trips when motor insulation decreases below 0.2-5M setting.
The thyristors must be protected against short circuit
Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits
Control
Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current
Displays LCD in 4 selectable languages and 8 LEDs
Keypad 6 clearly defined keys for easy setting
Aux. contact-immediate 1 C/O,8A,250V A. C,2000VA(delay 0-60 seconds)
Aux. contact-end of acceleration 1 C/O,8A,250V A. C,2000VA(del ay 0-120 seconds)
Fault contact 1 C/O,8A,250V A. C,2000VA(selectable as trip or trip fail safe)
Insulation alarm contact(optional) 1 C/O,8A,250V A. C,2000VA
Communication(optional) RS 485 with Modbus/ Profibus protocol for full control and supervision